AIR SPRINGS CAUSES OF PROBLEMS AND SOLUTIONS

AIR SPRINGS PROBLEMS, CAUSES AND SOLUTIONS

Deformed Air Springs

• Improper Storage

• Improper Handling

• Improper Transport

Solutions

• Storage According to ISO 5285 No Daylight, Dry, at Normal Room Temperature

• Avoid Improper Handling

• Avoid Improper Transport

Damage Of The Conical Beads and Cuts

• Improperly Mounted Bead Plate

• Pinching Of The Bellows With Metal Parts

Solutions

• Keep Conical Beads Clean and Corrosion Free

• Avoid Driving Without Pressure in The Air Suspension

Bellow Rubs Off at Shoulder

• Bead Plate Diameter Incorrect

• Bellows Too Long For Application

Solutions

• Make Sure to Use Original Parts

• Avoid Wrong Cross References

Broken Off Thread Bolts

• Excessive Torque

• Use of Oils or Lubricants

Solutions

• Do not Exceed Recommended Torque

• Avoid Usage of Oils or Lubricants

Overextension

• Spring Travel Not Restricted

• Incorrectly Adjusted Level Control

• Air Spring Not Suitable for Application

Solutions

• Check The Shock Absorbers

• Check and Adjust Level Control Valve

• Double Check If The Air Spring Fits The OE Part Number

Abrasion

• Bellows Contract with Chassis Parts

• Bellows Contract with Foreign Bodies

Solutions

• Double Check If The Air Spring Fits The OE Part Number

• Check Regularly and Remove Foreing

• Objects Stuck Between Bellows

Air Spring Bursting, Broken Piston

• Overload

• Exceeding the Maximum

• Allowable Pressure

Solutions

• Never Exceed the Maximal Allowed Weight of the Vehicle

Chemical Contamination

• Usage of Oils or Lubricants

Solutions

• Avoid Usage of Lubricants or Cleaners Which Containe Mineral Oils

• Check Air Springs on Regular Basis

 